Covidien Valleylab™ PolyHesive™ E7507 Corded Patient Return Electrodes
Covidien Valleylab™ PolyHesive™ E7507 Corded Patient Return Electrodes
Phone:+86-21-54286005
Microsystem
Endoscopysystem
Energysystem
Covidien Valleylab™ PolyHesive™ E7507 Corded Patient Return Electrodes
Phone:+86-21-54286005
A HOLISTIC SOLUTION TO PREVENT RETURN ELECTRODE INJURIES.
Designed to protect patients and your hospital
A PAD SOLUTION THAT STICKS.
REM Polyhesive™ II Patient Return Electrodes
Advanced patient monitoring for safety
Our REM™ contact quality monitoring system monitors patient-pad interface throughout a procedure. If the system detects elevated impedance or poor pad-to-patient contact at the patient return electrode, it sounds an alarm and deactivates the electrosurgical generator. Combined with our REM Polyhesive™ II patient return electrodes, they ensure safer electrosurgery for patients.
Polyhesive™ hydrogel
Made up of more than 70% water, it effectively bonds to the skin. And provides uniform contact over the entire pad surface area — without having to shave the patient.
With a thickness between 0.078 cm and 0.155 cm, it helps mitigate the potential for exposed foil “hot spots” on the pad surface.
Enhanced adhesion
An acrylic adhesive strip on the perimeter improves electrode-to-patient contact quality.
Flexible strength
Closed-cell foam backing conforms to any patient contour, preventing tearing of the return electrode.
Optimum size
A large surface area (21.25 sq. in./37 cm2) and a thick layer (0.050 in./0.127 cm) of Polyhesive™ hydrogel disperses current over a large area, minimizing heat production.
PAD SIZE MATTERS
A return electrode burn occurs when the heat produced, over time, is not safely dissipated by the size or conductivity of the patient return electrode (PRE).4 That’s why the return electrode size is important to patient safety.
E7507
137 cm2 (active area)
E7507 REM Polyhesive™ II patient return electrodes are designed and sized with patient safety in mind.
The active area of an E7510 infant REM Polyhesive™ II patient return electrode is approximately 75 cm2 and only indicated for patients up to 30 lbs.
E7510
75 cm2 (active area)
ORDER CODE | DESCRIPTION | UNIT OF MEASURE | QUANTITY |
---|---|---|---|
E7506- | Valleylab™ Non-REM Polyhesive™ Patient Return Electrode, 9' (2.7 m) | Case | 50 |
E7507 | Valleylab™ REM Polyhesive™ Adult Patient Return Electrode, 9' (2.7 m) | Case | 50 |
E7507-DB | Valleylab™ REM Polyhesive™ Adult Patient Return Electrode, 15' (4.6 m) | Case | 50 |
E7510-25 | Valleylab™ REM Polyhesive™ Infant Patient Return Electrode, 9' (2.7 m) | Case | 25 |
E7510-25DB | Valleylab™ REM Polyhesive™ Infant Patient Return Electrode, 15' (4.6 m) | Case | 25 |
E7512 | Valleylab™ REM Pad, Neonatal Hydrogel Patient Return Electrode 9' (2.7 m) | Case | 12 |