ETHICON ECH45C/S/L ECHELON™ 3000 45mm Stapler

ETHICON ECH45C ECH45S ECH45L ECHELON™ 3000 45mm Stapler

Phone:+86-21-54286005

Resources

ECHELON 3000 Stapler

Product Codes: ECH45C ECH45S ECH45L

Every surgery is different because every patient is different—which is why we built this device. The ECHELON 3000 Stapler enables greater access1 and more control2 over each transection, meeting the varying needs of each patient.

 

Features & Benefits

Greater Access

A 27% greater articulation span7 and a shorter articulation joint8 help surgeons access challenging anatomy, such as the tight pelvis region.9 For colorectal surgeons, this improved movement also increases the likelihood of transecting the colon in a single firing.10

更方便的访问

Easier Placement

A 39% wider jaw aperture can make placing the jaws on thick tissue easier, with potentially less tissue manipulation.11 For thoracic surgeons, this not only means improved access to the tight thoracic cavity9 but also easier placement on thick, variable lung tissue.12

更容易放置

 

More Control

Powered articulation that can be set to any point allows for more precision and one-handed use.13 For bariatric surgeons, this precise control over stapler placement can help in procedures like sleeve gastrectomies, where sleeve shape may impact both weight loss and acid reflux.

 

 

References

  1. Comparison of average maximum articulation span and jaw aperture between the ECHELON™ 3000 Stapler, ECHELON™+ Stapler, and Medtronic Signia™ Stapling System completed in 2022. (202654-220202)
  2. Compared to the legacy Powered Plus Stapler. (207534-220323)
  3. In benchtop testing in 4.0mm thick porcine stomach tissue, the ECHELON™ 3000 Stapler with GST60T had less mean longitudinal change compared to the Signia™ Stapling System with SIG60AXT: 0.549mm vs. 3.318mm, N=20 per group, P<0.0001. (208150-220330)
  4. Mean angle change analyzed in benchtop testing of distal tip movement between ECHELON™ 3000 Stapler with GST60W (0.35º) vs. Medtronic Signia™ Stapling System with EGIA60AVM (5.15º), N=28 per group, p < 0.001. (214166‐220519)
  5. On average, the ECHELON™ 3000 Stapler with GST60G and GST60T had a 0.26% malformed staple rate as compared to a 1.73% malformed staple rate for Signia™ with SIG60AXT and SIG60AXT on 3.0mm and 4.0mm target tissue, p < 0.001. (210298-220420)
  6. Rawlins L, Johnson BH, Johnston SS, et al. Comparative Effectiveness Assessment of Two Powered Surgical Stapling Platforms in Laparoscopic Sleeve Gastrectomy: A Retrospective Matched Study. Medical Devices: Evidence and Research. 2020:13 195–204. doi: https://doi.org/10.2147/MDER.S256237. Miller DL, Roy S, Kassis ES, et al. Impact of Powered and Tissue-Specific Endoscopic Stapling Technology on Clinical and Economic Outcomes of Video-Assisted Thoracic Surgery Lobectomy Procedures: A Retrospective, Observational Study. Adv Ther. 2018 Apr 16. doi: 10.1007/s12325-018-0679-z. Sylla P, Sagar P, Johnston S, et al.Outcomes associated with the use of a new powered circular stapler for left-sided colorectal reconstructions: a propensity score matching-adjusted indirect comparison with manual circular staplers. Surgical Endoscopy. 2021. doi: 10.1007/s00464-021-08542-7. (192176-211013)
  7. Comparison of average maximum articulation angle for ECHELON™ 3000 60mm Stapler (56.51°) vs. Medtronic Signia™ Stapling System 60mm (44.56°), p<0.05. (201022-220112).
  8.  Comparison of articulation joint length between ECHELON™ 3000 Stapler (28.4mm) vs. ECHELON™+ Stapler (38.7mm).
  9.  Comparison of maximum average articulation span between the ECHELON™ 3000 Stapler, ECHELON™+ Stapler, and Medtronic Signia™ Stapling System, p-value < 0.001. Maximum average articulation: 56.95°; 43.92°; 45.87° respectively. (205777-220309)
  10.  Angles of approach analyzed in CAD model based on 50th percentile male abdominal scans. (214011-220518)
  11. Comparison of average jaw aperture for ECHELON™ 3000 Stapler 60mm (22.79mm) vs. Medtronic Signia™ Stapling System 60mm (16.38mm), p<0.001. (202186-220126)
  12. Comparison of maximum average articulation span and maximum jaw aperture between the ECHELON™ 3000 Stapler, ECHELON™+ Stapler, and Medtronic
  13. Signia™ Stapling System, p-value < 0.001. Maximum average jaw aperture: 22.79mm; 17.11mm; 16.35mm respectively. Challenging tissue – varying thickness and density. (205778-220309)
  14. Control features include powered articulation and the ability to make articulation adjustments by 1°. (207540-220323)

Device Specifications and Comparisons

The ECHELON™ 3000 Stapler and reloads are intended for transection, resection, and/or creation of anastomoses.

Select Competitive Products: Medtronic Signia Stapling System

 

Featured Product

  ECHELON 3000 Stapler System
 

ECHELON 3000 Stapler System

Codes

ECH45C ECH45S ECH45L

Associated Reloads

  • GST45W
  • GST45B
  • GST45D
  • GST45G
  • GST45T

Description

  • 45mm laparoscopic stapler

Firing

Powered

Articulation

Powered

Shaft Length

  • Compact 28cm
  • Standard 34cm
  • Long 44cm

Degrees of Articulation

>110º

Staple Rows

6

Max Firings

12

Staple Form

B-Form

Qty./Box

3