Stapling deep within the pelvis presents clinical challenges. It can be difficult to achieve good staple formation, due to access and varying tissue conditions, and this may result in leaks. ECHELON CONTOUR™ Curved Cutter reduced risk factors for leaks,1 providing gentle tissue handling and a strong staple line without compromising healing.2
Gripping Surface Technology (GST)—a proprietary ridged surface on the staple reload—precisely compresses tissue only where needed for 31% reduced compressive forces on tissue and 37% less tissue trauma compared to traditional staplers.2
With a gentler curved design, 3D Stapling Technology minimized high stress points throughout the staple line3 and evenly distributed compression throughout the staple line3 to reduce potential leak pathways.3
Designed for increased visibility and optimal use in the narrower male pelvis, the unique curved head design of the ECHELON CONTOUR™ Curved Cutter gives low pelvic access and enhanced visibility of anatomic structures.4
1. Risk factors for leaks include the following: tissue trauma and a staple line with uneven compression. Benchtop testing on porcine colon comparing mean mucosal capture of 46.3% (n=30) for Echelon Contour to 74.46% (n=30) for Contour (p<0.05). Finite element-based computational simulations (FEA) on simulated porcine tissue measuring tissue compression after approximation and staple formation, comparing average standard deviation of 5.481 for 2D staples to 5.109 for 3D staples (n=37, p<0.05). (130579-200113)
2. Benchtop testing in porcine colon comparing mean compression load of 22.35 lbf (n=32) for ECHELON CONTOUR to 32.56 lbf (n=30) for CONTOUR (p<0.05) and comparing mean mucosal capture of 46.3% (n=30) for ECHELON CONTOUR to 74.46% (n=30) for Contour (p<0.05). (130577-200113)
3. Finite element-based computational simulations (FEA) on simulated porcine tissue measuring tissue compression after approximation and staple formation, comparing the area of maximum differentiation in standard deviation of 6.856 for 2D staples (n=1373) to 4.051 for 3D staples (n=1418) (P : Bonnett = 0.000/Levene = 0.000) and the area of maximum differentiation in standard deviation of 5.267 for 2D staples (n=2984) to 3.968 for 3D staples (n=2995) (P : Bonnett = 0.001/Levene = 0.016). (133427-200226)
4. Unique curved head design gives low pelvic access and enhanced visibility of anatomic structures (133984-200304)
The ECHELON CONTOUR™ Curved Cutter with Reload is intended for transection and resection in colorectal surgical procedures.
Select Competitive Products: Medtronic Endo GIA™ Radial Reload with Tri-Staple™ Technology
Featured Product |
|
ECHELON CONTOUR™ Curved Cutter |
|
---|---|
Codes |
GCS40B, GCS40G |
Associated Reload |
|
Description |
40mm Curved Cutter with Blue or Green Reload |
Device Technology |
Curved Head |
Size |
40mm |
Max Firings |
6 |
Staple Rows |
4 |
Closed Staple Height |
|
Tissue Thickness |
Regular, Thick |
Staple Technology |
GST + 3D |
Qty./Box |
|