ETHICON ECHELON FLEX™ PVE35A Powered Vascular Stapler
ETHICON ECHELON FLEX™ PVE35A Powered Vascular Stapler
Phone:+86-21-54286005
Microsystem
Endoscopysystem
Energysystem
EndoscopyConsumables
ETHICON ECHELON FLEX™ PVE35A Powered Vascular Stapler
Phone:+86-21-54286005
A 26% narrower curved, blunt tip anvil provides enhanced maneuverability around vascular structures compared to Endo GIA™ Curved Tip Reload with Tri-Staple™ Technology.1
Designed for 11% greater manual articulation in each direction for better access to difficult-to-reach vessels compared to Endo GIA™ Curved Tip Reload with Tri-Staple™ Technology.3
A 26% thinner shaft offers a 43.8º larger area of maneuverability in tight spaces compared to Endo GIA™ Curved Tip Reload with Tri-Staple™ Technology.2
1. Comparison of anvil widths for ECHELON FLEX™ Powered Vascular Stapler (PVE35A) vs. Endo GIA™ Curved Tip Reload with Tri-Staple™ Technology (EGIA30CTAVM). Measurement results: 7.0mm vs. 9.5mm respectively. (022305-210218)
2. Approach angles assessed in a virtual CAD environment in the 5th intercostal space. (022307-141001)
3. Based on articulation data from IFUs of each device. (066276-211027)
4. Miller DL, et al. Impact of powered and tissue-specific endoscopic stapling technology on clinical and economic outcomes of video-assisted thoracic surgery lobectomy procedures: a retrospective, observational study. Review of 1,051 cases between 2015 and 2016 from the Premier Healthcare Database (4.8% vs 14.2%, p=0.010). (084009‐180619)
5. Park SY, Kim DJ, Nam CM, et al. Clinical and Economic Benefits Associated with the Use of Powered and Tissue-specific Endoscopic Staplers Among Patients Undergoing Thoracoscopic Lobectomy for Lung Cancer. Journal of Medical Economics, DOI: 10.1080/13696998.2019.1634081. Review of 275 cases between 2008 and 2016 from Yonsei University College of Medicine, Seoul, Korea (182.4 ± 328.7ml vs. 79.8 ± 110.0ml; p=0.0004). (119699‐190730)
6. Park SY, Kim DJ, Nam CM, et al. Clinical and Economic benefits Associated with the Use of Powered and Tissue‐specific Endoscopic Staplers Among Patients Undergoing Thoracoscopic Lobectomy for Lung Cancer. Journal of Medical Economics, DOI: 10.1080/13696998.2019.1634081. Review of 275 cases between 2008 and 2016 from Yonsei University College of Medicine, Seoul, Korea ($12,281 vs. $10,822; p<0.0001). (119701‐190730)
7. Miller DL, Roy S, Kassis ES, et al. Impact of Powered and Tissue‐ Specific Endoscopic Stapling Technology on Clinical and Economic Outcomes of Video‐ Assisted Thoracic Surgery Lobectomy Procedures: A Retrospective, Observational Study. Adv Ther. 2018 Apr 16. doi: 10.1007/s12325‐ 018‐0679‐z. Review of 1,051 cases between 2015 and 2016 from the Premier Healthcare Database. Length of stay: 4.99 vs 5.82; p=0.047. (087826‐180628)
8. Park SY, Kim DJ, Nam CM, et al. Clinical and Economic benefits Associated with the Use of Powered and Tissue‐specific Endoscopic Staplers Among Patients Undergoing Thoracoscopic Lobectomy for Lung Cancer. Journal of Medical Economics, DOI: 10.1080/13696998.2019.1634081. Review of 275 cases between 2008 and 2016 from Yonsei University College of Medicine, Seoul, Korea (189.9 min vs 137.1 min, p < 0.0001). (119700‐190730)
The ECHELON FLEX™ Powered Vascular Stapler is designed for use with ENDOPATH ECHELON Vascular White Reloads.
Select Competitive Products: Endo GIA™ Curved Tip Reload with Tri-Staple™ Technology
Featured Product |
|
ECHELON FLEX™ Powered Vascular Stapler |
|
---|---|
Codes |
PVE35A |
Associated Reloads |
VASECR35 |
Description |
35mm Vascular Linear Cutter |
Firing |
Powered |
Articulation |
Manual |
Shaft Length |
32cm |
Degrees of Articulation |
100º |
Staple Rows |
4 |
Max Firings |
12 |
Size |
35mm |
Staple Form |
B-Form |
Qty./Box |
3 |